Schneider Electric LADT2 TeSys D Time Delay Auxiliary Contact Block – 1NO + 1NC, 1–30s

119.23 AED
In Stock

The Schneider Electric LADT2 TeSys D Time Delay Auxiliary Contact Block is a front-mounted 1NO + 1NC time-delay auxiliary module designed for TeSys D / TeSys Deca contactors and compatible TeSys F contactors and CAD control relays. It provides an on-delay function with a 1–30 second adjustable delay range, screw-clamp terminals, and a 690V AC rated operational voltage, making it suitable for industrial motor-control sequencing and automation applications.

In Stock
Add to wishlist1 person favorited this product

Description

The Schneider Electric LADT2 TeSys D Time Delay Auxiliary Contact Block is designed to add time-delay functionality to compatible Schneider Electric contactors and control relays. It provides 1 normally open (NO) and 1 normally closed (NC) contact, allowing control circuits to introduce a controlled delay during contactor operation.

The LADT2 is an on-delay timer, with the commonly specified adjustable time range of 1 to 30 seconds. Schneider Electric also identifies the LADT2 family with selectable time-delay ranges including 0.3–3 seconds, 1–30 seconds, and 10–180 seconds, depending on the corresponding timer version/configuration. For this LADT2 reference, the Schneider product documentation identifies the 1–30 second on-delay range.

The module provides 1NO + 1NC time-delay contacts and is designed for front mounting on compatible TeSys contactors. Its screw-clamp terminals provide a secure and practical connection method for industrial control wiring.

The LADT2 is compatible with TeSys Deca CAD control relays, TeSys Deca LC1D contactors, and TeSys F LC1F contactors, making it useful for both new installations and retrofit applications.

With a rated operational voltage of up to 690V AC at 25–400Hz and a conventional free-air thermal current of 10A at 60°C, the Schneider LADT2 is suitable for a wide range of industrial control and signaling circuits. Its contact ratings include 6A at 120V AC-15 and 1.04A at 690V AC-15.

The LADT2 time delay auxiliary contact block is particularly useful where controlled sequencing is required, including motor starting circuits, pump control, conveyor systems, HVAC equipment, industrial automation, interlocking, and delayed switching applications.

Specification Details
Manufacturer Schneider Electric
Product Range TeSys D / TeSys Deca
Model / Reference LADT2
Product Type Time Delay Auxiliary Contact Block
Contact Composition 1 NO + 1 NC
Contact Operation Time Delay
Timer Type On Delay
Time Delay Range 1–30 seconds
Mounting Location Front
Rated Operational Voltage (Ue) 690V AC, 25–400Hz
Rated Operational Current (Ie) 6A at 120V AC-15; 1.04A at 690V AC-15
DC Utilization Rating 0.55A at 125V DC-13; 0.1A at 600V DC-13
Conventional Free-Air Thermal Current (Ith) 10A at 60°C
Rated Insulation Voltage (Ui) 690V IEC 60947-5-1
Terminals Screw-clamp terminals
Mounting Type Clip-on front mounting
Compatibility TeSys Deca CAD, LC1D, LC1F / TeSys F
Minimum Switching Current 5mA
Minimum Switching Voltage 17V
Insulation Resistance >10 MΩ
Rated Making Capacity (Irms) 140A
Permissible Short-Time Rating 100A at 60°C / 1s; 120A / 500ms; 140A / 100ms
Protection 10A gG fuse
Standards EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, GB/T 14048.5
Certifications IECEE CB Scheme, UL, CSA, CCC, EAC, UKCA
Weight 0.074kg
SKU MAS03119LADT2

Key Features

  • 1NO + 1NC time-delay auxiliary contacts
  • 1–30 second adjustable on-delay
  • Designed for Schneider TeSys D / TeSys Deca contactors
  • Compatible with selected TeSys F LC1F contactors
  • Compatible with CAD control relays
  • Front-mounted design
  • Clip-on installation
  • Screw-clamp terminals
  • Rated up to 690V AC
  • 10A thermal current at 60°C
  • 6A AC-15 at 120V
  • Compact solution for contactor sequencing
  • Suitable for industrial automation and HVAC applications
  • Supports delayed motor-control operations
  • Multiple international certifications
  • Suitable for new installations and retrofit applications
  •  

Applications

The Schneider Electric LADT2 is suitable for:

  • Motor control panels
  • DOL motor starter circuits
  • Industrial automation
  • Pump control systems
  • Conveyor systems
  • HVAC control panels
  • Compressor control
  • Industrial machinery
  • Motor sequencing
  • Delayed switching circuits
  • Control-panel interlocking
  • PLC interface and control circuits
  • Industrial process automation
  • Delayed start/stop functions
  • Contactor control and sequencing

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.